E-FS Series
FireShield Fire Alarm Control Panel Conventional 1, 3, 5 & 10 Zones
Description
|
The E-FS Series Panels are discontinued and have been replaced by E-FSC Series conventional panels. Please click here for more information.
|
Link to this product
|
Catalog Numbers
| Catalog Number
|
Description
|
|||||||
Specifications
Approvals
Agency Approvals| Cat. No. | Name | Function |
| BC-2 | Battery Cabinet | Gray battery box - holds two batteries |
| BC-2R | Battery Cabinet | Red battery box - holds two batteries |
| CTM4.7 | City Tie Module | Reporting events to local energy Master fire alarm box |
| EOL36-11 | End-of-line Resistor | One 3.6K resistor and one 1.1K resistor |
| FSAT Series | Trim Plate | 1, 2, 3 or 4 gang trim plate (white, red or gray) for Remote Annunciator |
| FS-DACT | DACT/Dialer | Reporting events to a remote monitoring facility |
| FSCU | Configuration Software | PC downloading of configuration and event history |
| FSRRM | Relay Module | Five Form C relays (1A each) - configurable as zone or common system mode |
| FSRRM-S11 | 11 in. Mounting track | Mounting track for 2-4 FSRRMs. Mounts in MFC-A or other listed FA enclosure |
| FSRSI | Remote System Indicator | Remote Annunciator Module - common LEDs & sounder w/silence |
| FSRZI-A | Remote Zone Indicator | Remote Annunciator Module - 5 Zone LEDs |
| FSTRIM35G or FSTRIM35R | 3 & 5 Zone Trim Ring | Semi-flush mounting of 3 & 5 zone panels (gray or red) |
| FSTRIM10G or FSTRIM10R | 10 Zone Trim Ring | Semi-flush moutning of 10 zone panels (gray or red) |
| MFC-A | FSRRM Mounting Cabinet | Holds up to 4 FSRRM Modules when used with optional FSRRM-11 snap-track |
| RPM | Reverse Polarity Module | Reporting alarm status to remote monitoring facility |
| XTR3A120 | Power Supply Expander | Expands 10 zone panel with 2.5 amps additional power |
Documentation
Fire Panel Programming Software
- FSA-CU_Setup_v3.3.zip
Configuration utility program for E-FS, E-FSC, and E-FSA fire alarm panels. Copy FSA-CU_Setup_v3.3.zip file to your hard drive, unzip it, then click on the FSA-CU_Setup application to install.
Technical Bulletins
- FireShield_All_DWG.zip
FireShield Drawings in DWG format
- FireShield_All_Illustrator.zip
All FireShield Drawings in Illustrator 9.0 format
- FireShield_All_PDF.zip
All FireShield Drawings in PDF format
- FireShield_All_TIF.zip
- FireShield_All_WMF.zip
All FireShield Drawings in WMF format
- IDC_ClassA.zip
Drawings for IDC Wiring - Class A
- IDC_ClassB.zip
Wiring of IDC on FireShield - Class B Drawings in Illustrator 9.0, WMF, DWG, TIF or PDF formats.
- Motherboard.zip
FireShield Motherboard Drawings in Illustrator 9.0, WMF, DWG, TIF and PDF formats
- NAC_ClassA.zip
FireShield NAC Drawings - Class A Drawings in Illustrator 9.0, WMF, TIF, DWG and PDF formats
- NAC_ClassB.zip
Wiring for NAC - Class B Drawings in Illustrator 9, DWG, WMF, TIF and PDF formats
- Power_Supply.zip
FireShield Power Supply Drawings Drawings in Illustrator 9, WMF, TIF, DWG and PDF formats
- Remote_Modules.zip
Remote Module Wiring Drawings in Illustrator 9, WMF, TIF, DWG and PDF formats
- Remote_Sys_Ind_Mtg.zip
Mounting the FSRSI Drawings in Illustrator 9, WMF, DWG, TIF and PDF formats
- Remote_Zone_Ind_Mtg.zip
Mounting the FSRZI Drawings in Illustrator 9, WMF, TIF, DWG and PDF formats
- Waterflow_Supervisory.zip
Waterflow and Supervisory Wiring Drawings in Illustrator 9, WMF, DWG, TIF and PDF formats
- AE Bulletin, Electromechanical Noise Part II
Tips on dealing with electromechanical devices, and the electrical noise they can generate on fire alarm circuits.
- AE Bulletin, Door Holders and Fire Alarm
Tips on how to connect door holders to fire alarm systems.